If the wiring connections are okay then one or both of the user interface control assemblies may need to be replaced. Check the wire harness connections between the main electronic control board and the user interface assemblies visually and with a multi-meter. Check the wire harness connections between the user interface assemblies visually and with a multi-meter.
#WHIRLPOOL DUET STEAM DRYER CODE#
Whirlpool Duet Dryer Error Code = F72 – F78Įrror Condition = User Interface Control Assembly FailĬheck or Repair Needed = Remove power from the dryer. Replacement Parts = Main Electronic Control Board – User Interface Control If the connections are okay then the main electronic control board and the user interface control assemblies may need to be replaced. Check the wire harnesses visually and with a multi-meter from the electronic control board and the user interface control board. Whirlpool Duet Dryer Error Code = F70/F71Įrror Condition = No communication between the ECB (electronic control board) and the UICB (user interface control board assembly)Ĭheck or Repair Needed = Remove power from the dryer. Clear lint blockage restriction from the air vent exhaust system.
Remove fabric softener buildup on the lint screen if necessary. If the wiring connections are okay then replace the moisture sensor.Įrror Condition = Restricted Outlet AirflowĬheck or Repair Needed = Check the lint screen filter and clean of any lint. Check the wiring harness on the moisture sensor visually and with a multi-meter. If the inlet temperature sensor is bad then replace it.Ĭheck or Repair Needed = Remove power from the dryer. Use a multi-meter and check the resistance of that particular thermistor/temp sensor (50,000 ohms). Replacement Parts = High Limit Thermostat – Inlet Thermistor (Temp Sensor)Ĭheck or Repair Needed = The controller indicates an electrical shorted inlet temperature sensor (thermistor).
NOTE: The inlet thermistor is part of the high limit thermostat on this dryer. If the inlet temperature sensor is bad then replace it. Replacement Parts = Outlet Thermistor (Temp Sensor)Įrror Condition = Inlet Thermistor (Temp Sensor) FailĬheck or Repair Needed = The controller indicates an electrically open inlet temperature sensor (thermistor). If the outlet temperature sensor is bad then replace it. Use a multi-meter and check the resistance of that particular thermistor/temp sensor (10,000 ohms). Error Condition = Outlet Thermistor (Temp Sensor) FailĬheck or Repair Needed = The controller indicates an electrically open outlet temperature sensor (thermistor).